RAISED BED A and B

RAISED BED A and B


Parts List

Water Source Connection Fittings

ITEM A B DESCRIPTION PART #
1 1 Y Filter 3/4" Female Hose Swivel x Male Hose 150 Mesh Stainless Steel Screen
 
A4-HTF155
1 1 Pressure Regulator 20 PSI - Hose Threaded 3/4" FHT x 3/4" MHT
 
DD-HPR35
1 1 Direct-Loc Swivel Adapter .600 ID DL x 3/4" FHT Swivel - 700 or 710 Tubing
 
DL-FHS600

1/2 Tubing Directional and Raised Bed Connection Fittings

  A B ITEMS PART #
7 16 Direct-Loc Elbow .600 ID DL x DL - 700 or 710 Tubing
 
DL-L600
3 7 Direct-Loc Tee .600 ID - 700 or 710 Tubing
 
DL-T600
1 2 Direct-Loc Coupling .600" ID - 700 or 710 Tubing
 
DL-C600
4 8 Direct-Loc Flow Control/Shut Off Valve
 
DL-FCV600
4 8 Direct-Loc End Cap .600 ID DL x 3/4" MHT w/ Cap - 700 or 710 Tubing
 
DL-EC600
1 0 1/2" x 50' .700 OD Poly Tubing - 50' Roll
 
DD-DH700-50
0 1 1/2" x 100' .700 OD Poly Tubing - 100' Roll
 
DD-DH700-100
10 20 1/2" Tubing Mounting Clamp with Nail - Black
 
DD-MC700B
1 1 Hole Punch for 1/4" Barbed Fittings & Drippers
 
DD-KP
30 50 1/4" Barbed Connector
 
DD-C250
1 2 1/4" x 100' Soaker Hose Dripline 6" Spacing 1/2 GPH Dripline Irrigation Emitters - Black Tubing
 
DD-DET250-6-100
30 50 Goof Plug - Dual End 1/4" & 1/8"
 
DD-GP
40 80 Micro Tubing Holder Stake 6" - Multiple sizes .167" to .350" OD
 
DD-S2
1 2 Drip Tubing Hold Down 8" Wire Stake "J Style" fits 1/8" to 3/4" tubing - 25 Pack
 
TLS6

 

RAISED BED A and B

Instructions:
1. Layout 1/2” Main Line to boxes using directional fittings provided in kit. See sample layouts on page 2 and 3.
2. Once 1/2” line is in place, use hole punch to poke into line at desired row location (take care to ensure the hole is punched at a 90 degree angle to the intended row to minimize leaking at the main line.
3. Cut 1/4” Drip Emitter Tubing to desired length for each row, and insert a DD-C250 into one end of the tubing (this makes it easier to insert into your 1/2” line)
4. Insert DD-C250 into pre-punched holes.
5. Secure with stakes provided in kit.
6. Assemble Water Source Connections as shown in illustrations and attach main line using the Perma Lock fittings provided in the kit. Winterization Tips

1. Remove Timer (if installed on your system), filter, and pressure regulator and store indoors.
2. Remove End Caps (DL-EC600) from main lines, Goof Plugs do not need to be removed. Allow lines to self drain, and or blow out lines with a Shop Vacuum or similar (do not use heavy compression air to blow out lines. Replace Caps. Drip Irrigation Lines are usually very tolerant to winter so some water in the lines will not usually have any impact on system performance year to year.
 

Purchase Here:

 

Maintenance Tips:  

WINTERIZING: For instructions click here

For more information on Drip Irrigation Design and Installation click here

 

Ref 5300